Silence the stove detector's queue overflow and fix notify calls in stove and HVAC blueprints
Stove: added max_exceeded: silent (mode: queued, max: 10 kept as-is) since the ~1/s sensor cadence keeps the queue full by design. Fixed five broken notify calls (rise, matched fall, unmatched fall, out-of-window edge, cycle timeout) that rendered notify_target's target-selector dict into the service name instead of resolving it, replacing each with notify.send_message + target: !input notify_target. HVAC: same fix at its one notify call, after confirming its notify_target input is the same target selector. Claude-Session: https://claude.ai/code/session_017vaW5jtjrCqhV9nUDr8mQa
This commit is contained in:
@@ -140,7 +140,8 @@ action:
|
||||
- choose:
|
||||
- conditions: "{{ notify_target | length > 0 }}"
|
||||
sequence:
|
||||
- service: notify.{{ notify_target }}
|
||||
- service: notify.send_message
|
||||
target: !input notify_target
|
||||
data:
|
||||
message: >
|
||||
HVAC '{{ hvac_action }}' action for {{ interval }} minutes showed ineffective operation.
|
||||
|
||||
Reference in New Issue
Block a user