Files
lanework/KanbanTests
rzen 6d1872ad8b The harness waits for the masonry it aims at — sixty settle turns before the first click
Under parallel-build load the six-turn settle let the first click land before the masonry's measurement passes did, on the empty-space layer instead of a card — which the dragless layer holds forever in a sterile queue, reading as a dead click. Bisect-verified environmental (same failure at every commit back to the suite's birth); with the settle, click → selection in 41 ms.

Claude-Session: https://claude.ai/code/session_014PtZdPwqZuqEDLc6wZMtEy
2026-08-08 10:25:31 -04:00
..